TITAN KRIOS
G4 TEM
The Titan Krios G4 TEM is a 300 kV cryo-electron microscope for high-resolution single-particle cryo-EM and cryo-electron tomography. Equipped with a Cold Field Emission Gun (E-CFEG) and Falcon 4i camera, it delivers exceptional imaging of biological specimens.
Key Features
- 300 kV
- Cold Field Emission Gun (E-CFEG)
- 3 Condenser Lens Parallel Beam Zoom
- 1.2 Å resolution (information limit)
- Computer-controlled compustage
- +/- 70° single-tilt specimen stage
- Cs = 2.7 mm
- Cc = 2.7 mm
- Automated specimen handling system (the FEI Autoloader)
- Automated liquid nitrogen cooling system
- Selectris X Energy Filter
- Falcon 4i Camera
- TFS Xplorer3D data acquisition and processing system
- EPU-S Acquisition System
- Tomography and Tomo Live for acquisition and data processing
- CryoSPARC Live for data processing
Titan Krios Operation
Titan Krios Operation
The Titan Krios transmission electron microscope is open for usage for all internal and external users. Instructions to become a user can be found here: EICN Become a User. Training can be requested by emailing eicnhelp@cnsi.ucla.edu. If you do not receive a reply within 48 hours, you can email Matthew Mecklenburg (mmecklenburg@cnsi.ucla.edu) to follow up.
Typical Operation of Titan Krios for first-time users includes 3-4 hours of assisted usage, in addition to the Titan Krios hourly rate. Please see here for our current recharge rates: EICN Policy and Rates.
Assisted usage includes:
- Approximately 1 hour to load your sample*
- Approximately 1-2 hours to set up the microscope including alignment and mapping
- Approximately 1 hour to set up data collection software (single particle or tomography).
- If necessary, additional hours to train the user on the system. This is based on the user’s experience and familiarity with the system.
- When the Titan Krios is ready, you can start collecting images and processing your data on your own.
*Remember to bring your prepared samples on grids to our lab or ship them here prior to your arrival. Email us at eicnhelp@cnsi.ucla.edu for the address.
Supplies provided by EICN will be charged at cost. (Carbon Film Grids: $5/each, Quantifoil Grids: $15 each, Auto Grids: $30 each, etc.)
Additional consumable fees may apply (e.g., $30 per autogrid). Autogrid packs of 10 are available from EICN at cost.Cold Field Emission Gun (E-CFEG)
Regular Rates
- Internal Academic: $70/hour
- External Academic: $95/hour
- Industry: $140/hour